166 ENVIRONMENT OF CARE TABLE OF CONTENTS 1. Clinical and Alert Alarms ..............................................................................................................167 Management plan, equipment inventory, testing, response process 2. Occupational Slip, Trip, and Fall Prevention.............................................................................. 168 3. Fire Safety P ................................................................................................................................. 169 Perioperative fire safety plan, fire triangle, fire risk assessment, interventions, flammable antiseptic agents, flammable liquid storage, anesthesia gas connection, airway fires, fire suppression, evacuation, fire extinguishers, fire safety training 4. Electrical Equipment .................................................................................................................... 176 Inspection, safe practices 5. Warming Cabinets ........................................................................................................................ 177 Blanket warming, solution warming, cabinet malfunctions 6. Medical Gas Cylinders .................................................................................................................. 178 Storage, transport, safe use practices 7. Waste Anesthetic Gases P .......................................................................................................... 180 8. Latex-Safe Environment P ........................................................................................................... 181 9. Hazardous Chemicals ................................................................................................................... 183 Chemical safety plan, storage, handling, spill management, personal protective equipment, eyewash stations, methyl methacrylate, glutaraldehyde, formaldehyde 10. Waste Management ................................................................................................................... 188 11. Quality .......................................................................................................................................... 188 Damage assessment, restoration measures, power failure, communications system failure, HVAC system failure MEDICAL ABBREVIATIONS & ACRONYMS CMS – Centers for Medicare and Medicaid Services FDA – US Food and Drug Administration IFU – Instructions for use MAUDE – Manufacturer and User Facility Device Experience MMA – Methyl methacrylate NFPA – National Fire Protection Association NIOSH – National Institute for Occupational Safety and Health OR – Operating room OSHA – Occupational Safety and Health Administration PPE – Personal protective equipment ppm – Parts per million REL – Recommended exposure limit RN – Registered nurse SDS – Safety data sheet STEL – Short-term exposure limit VR – Virtual reality WAG – Waste anesthetic gas P indicates a recommendation or evidence relevant to pediatric care. I-05_EOC-25_103124.indd 166 I-05_EOC-25_103124.indd 166 11/7/2024 10:45:27 AM 11/7/2024 10:45:27 AM
ENVIRONMENT OF CARE 167 T he Guideline for a Safe Environment of Care was approved by the AORN Guidelines Advisory Board and became effective as of December 21, 2023. Infor- mation about the systematic review supporting this guide- line, including the PROSPERO registration number, system- atic review questions, description of the search strategy and evidence review, PRISMA 2020 flow diagram, evidence rating model, and evidence summary table is available at https://www.aorn.org/evidencetables/. Purpose This document provides guidance for maintaining a safe environment of care for patients and perioperative person- nel. The recommendations include information on • clinical alarms and alert alarms, • occupational injuries (ie, slips, trips, and falls), • fire safety, • electrical equipment, • blanket and fluid warming cabinets, • medical gas cylinders, • waste anesthetic gases, • a latex-safe environment, • hazardous chemicals, and • waste management. The following topics are outside the scope of this document: • chemotherapeutic agents and disposal of medications (See the AORN Guideline for Medication Safety1); • environmental stewardship (See the AORN Guideline for Design and Maintenance of the Surgical Suite2 and the AORN Position Statement on Environmental Responsibility3) • heating, ventilation, and air conditioning (See the AORN Guideline for Design and Maintenance of the Surgical Suite2); • use of lifting equipment and moving patients (See the AORN Guideline for Safe Patient Handling and Mobility4); • noise and distractions (See the AORN Guideline for Team Com- munication5 and the AORN Position Statement on Managing Distractions and Noise During Perioperative Patient Care6); • patient injuries related to incorrect tubing connections (See the AORN Guideline for Medication Safety1); • personnel injuries related to exposure to bloodborne pathogens (See the AORN Guideline for Transmission- Based Precautions7 and Guideline for Sharps Safety8); • product evaluation (See the AORN Guideline for Medical Device and Product Evaluation9); • radiation safety (See the AORN Guideline for Radiation Safety10); • handling and disposal of radionuclides and radiopharma- ceuticals (See the AORN Guideline for Radiation Safety10); • sterilization methods using hydrogen peroxide, peracetic acid, ozone, and ethylene oxide (See the AORN Guideline for Sterilization11); • high-level disinfectants and liquid chemical sterilants used for processing flexible endoscopes (See the AORN Guideline for Processing Flexible Endoscopes12 and Guideline for Man- ual High-Level Disinfection13) • surgical smoke (See the AORN Guideline for Surgical Smoke Safety14); and • workplace violence (eg, active shooter, lateral violence). 1. Clinical and Alert Alarms 1.1 Convene an interdisciplinary team with the responsibility and authority to develop and imple- ment a perioperative clinical and alert alarm man- agement plan.15 [Recommendation] 1.1.1 The interdisciplinary team should include perioperative registered nurses (RNs), sur- geons, anesthesia professionals, biomedical and facility engineering personnel, quality and risk management personnel, and other stakeholders identified by the organization. [Recommendation] 1.1.2 The perioperative clinical and alert alarm management plan should include • perioperative clinical alarm policy and pro- cedure development and review; • an inventory of the clinical alarms found in the perioperative area that is updated when new equipment is added16-18 (See Rec- ommendation 1.2); • procedures for responding to various clini- cal and alert alarms, including who should respond to which alarms17,19; • criteria for changing default clinical and alert alarm settings, including who is allowed to make changes17,18; • criteria for disabling or turning off a clini- cal or alert alarm20,21; • procedures for communicating changes to clinical and alert alarm settings20 (See Rec- ommendation 1.5); • the frequency of and procedures for testing and maintenance of clinical and alert alarm systems18-20 (See Recommendation 1.3); 2025 Guidelines for Perioperative Practice Last revised: December 2023. Copyright © 2025 AORN, Inc. All rights reserved. GUIDELINE FOR A SAFE ENVIRONMENT OF CARE I-05_EOC-25_103124.indd 167 I-05_EOC-25_103124.indd 167 11/7/2024 10:45:27 AM 11/7/2024 10:45:27 AM
168 ENVIRONMENT OF CARE • processes to reduce clinical alarm fatigue, including strategies to mitigate clinically insignificant alarms16-19,21; • processes for reporting malfunctions, near misses, and adverse events associated with clinical and alert alarms16-19,21; • education and competency verification17-21; and • processes for monitoring adherence to clin- ical and alert alarm management policies and procedures.18 [Recommendation] 1.2 Collaborate with biomedical and facility engineering personnel to conduct an inventory of equipment and systems with clinical and alert alarms in the peri- operative or procedural areas. [Recommendation] Completing an alarm inventory assists with iden- tifying equipment and systems that have alarms, maintaining an accurate alarm inventory, and moni- toring adherence to regularly scheduled testing and maintenance of the alarms.18 Clinical alarms alert personnel to changes in an indi- vidual patient’s status or condition and can include alarms associated with patient monitoring devices (eg, cardiac monitors, oximeters), ventilators, infusion and irrigation pumps, intermittent pneumatic compression devices, pneumatic tourniquets, and gas insufflators. Alert alarms indicate system failures that could affect the safety of multiple patients and personnel and are often associated with medical gas systems; heating, ventilation, and air conditioning systems (eg, tempera- ture, humidity); refrigerators, freezers, or warmers; electrosurgical units; fire detection; and security. 1.3 Test clinical and alert alarms • upon initial setup22 and before use of the device or equipment, • according to the device or equipment manufac- turer’s instructions for use, • before returning the device or equipment to service after completion of repairs or mainte- nance, and • at established intervals defined in the clinical alarm management plan. [Recommendation] Testing provides verification that alarms are functioning properly.16-18,21 1.4 Verify clinical and alert alarms are audible by • adjusting the volume of alarms to make them distinguishable from competing noise and • reducing ambient noise so that alarms can be heard. [Recommendation] Patients have experienced injuries and near misses because alarms were turned off or inaudible.20,21 In addition, noise makes it difficult to hear and differen- tiate among alarms.19,21 Sources of ambient noise in the operating room (OR) include equipment (eg, clini- cal and alert alarms, ventilation systems, powered instruments, suction devices, electrosurgical units) and personnel (eg, conversation, music). Some noise is unavoidable in the perioperative environment, but certain sources of noise (eg, volume of music and conversation) are within the control of the perioper- ative team. See the AORN Guideline for Team Communica- tion5 for strategies to reduce noise in the OR. 1.5 Communicate changes in clinical alarm settings (eg, high or low limits) verbally and visually (eg, with a posted sign) during changes of personnel. [Recommendation] Communicating changes to clinical alarm settings from default parameters prepares oncoming person- nel to respond appropriately.20 1.6 Establish and implement a process for responding to alert alarms when perioperative personnel are not present. [Recommendation] Critical supplies (eg, blood bank refrigerator, tis- sue freezer) located in areas of the perioperative suite that are not staffed 24 hours per day could be compromised if storage conditions fall outside of set parameters and the associated alert alarm systems are not monitored. 1.6.1 Collaborate with biomedical and facility engi- neering personnel to configure alert alarms for remote monitoring when perioperative personnel are not present. [Recommendation] 2. Occupational Slip, Trip, and Fall Prevention 2.1 Convene an interdisciplinary team with the responsibility and authority to develop, imple- ment, and maintain an occupational slip, trip, and fall prevention program that is specific to the peri- operative and procedural setting. [Recommendation] The National Institute for Occupational Safety and Health (NIOSH)23 recommends creating an occupa- tional slip, trip, and fall prevention program. Experts in the field of ergonomics support NIOSH’s recom- mendation.24-28 Slips, trips, and falls account for 25% of injuries experienced by RNs and represent the most frequent type of nonfatal occupational injury among RNs who are older than 64 years.25 Occupational inju- ries can impair a perioperative team member’s ability I-05_EOC-25_103124.indd 168 I-05_EOC-25_103124.indd 168 11/7/2024 10:45:27 AM 11/7/2024 10:45:27 AM
169 ENVIRONMENT OF CARE to do their job in caring for patients, increase work- related compensation claims, lead to lost workdays, and reduce productivity.23 2.1.1 The interdisciplinary team should include peri- operative RNs, surgeons, anesthesia profes- sionals, surgical technologists, environmental services personnel, risk management/quality personnel, occupational health professionals, and other stakeholders identified by the orga- nization. [Recommendation] 2.1.2 The occupational slip, trip, and fall preven- tion program should include • regular assessment of environmental hazards24,29; • systematic collection and review of occupa- tional slip, trip, and fall incident data within the health care organization23,24; • implementation of slip, trip, and fall pre- vention strategies (eg, those listed in Rec- ommendation 2.2); • education on slip, trip, and fall prevention strategies23; • checklists to evaluate implementation of slip, trip, and fall prevention strategies23; • procedures for ◦routine floor cleaning, ◦managing spills (ie, reporting spills and associated hazards [eg, damaged flooring], spill clean-up), and ◦reporting slip, trip, and fall injuries23; • routine sharing of organizational slip, trip, and fall incident trends with all members of the perioperative team; and • evaluation of program performance.23 [Recommendation] Regular assessment of environmental hazards and review of slip, trip, and fall incidents within the organization can help identify risk factors that contribute to these events; which types of slip, trip, and fall events are most common; and spe- cific locations where multiple slip, trip, and fall events occur (ie, “hot spots”)23 so that targeted preventive measures can be implemented.23,24,29 See Section 11: Quality for information about using data and trends for performance improvement. 2.2 Implement the following strategies to minimize slips, trips, and falls: • arrange equipment and supplies to provide unobstructed pathways,23,27,28 • clean up spills or debris immediately,23,24,26,27 • repair flooring surface irregularities (eg, dam- age, uneven surfaces),23,24,27 • cover electrical cords that are on the floor with a facility-approved floor cord covering,28 • reduce clutter and the number of electrical cables on the floor,23,24,27,30 • provide adequate lighting,23,24,27,28,30 • post signs warning of wet floor hazards,23,24,26,28 and • wear slip-resistant shoes.8,10,12,13 [Recommendation] Perioperative personnel are at the greatest risk for occupational slips, trips, and falls associated with exposure to spills, body fluids, and slippery walking surfaces.23 Dim lighting in the OR, which frequently occurs during minimally invasive surgery, can con- tribute to slips, trips, and falls. The nature of work- ing in dimly lit ORs during minimally invasive sur- gery requires perioperative team members to shift from areas of high illumination to areas with lower levels of illumination. This visual adaptation can contribute to difficulty seeing, particularly when it obscures the view of walkways.28 See the AORN Guideline for Design and Mainte- nance of the Surgical Suite2 for guidance related to design and maintenance considerations (eg, lighting, flooring materials, floor repairs) and the AORN Guideline for Environmental Cleaning31 for guidance related to floor cleaning procedures and cleaning product selection. 3. Fire Safety 3.1 Convene an interdisciplinary team with the responsibility and authority to develop a fire safety plan that is specific to the perioperative area.32-35 [Recommendation] 3.1.1 The interdisciplinary team should include peri- operative RNs, surgeons, anesthesia profession- als, surgical technologists, risk management/ quality professionals, facility engineers, bio- medical engineers, and other stakeholders iden- tified by the organization. [Recommendation] 3.1.2 Include the following in the perioperative fire safety plan: • a review of the NFPA 99 Health Care Facilities Code36 and the NFPA 101 Life Safety Code37; • perioperative team members’ roles33,38,39; • communication procedures32,40,41; • strategies for fire prevention33,38; • processes for management of different fire scenarios (eg, airway, non-airway)33,38; • fire alarm activation procedures35,42,43; • methods to contain and extinguish a fire32,33,35,44; I-05_EOC-25_103124.indd 169 I-05_EOC-25_103124.indd 169 11/7/2024 10:45:27 AM 11/7/2024 10:45:27 AM
170 ENVIRONMENT OF CARE • procedures for evacuation and routes32,33,45; • a description of the facility’s process for assessing fire risk (eg, when, who, how); • cognitive aids (eg, algorithms, checklists) to support fire prevention and management interventions38,46-50; • procedures for reporting fire events and near misses32,51-54; • the required content for, frequency, and methods (eg, simulation training) of fire safety education; and • the frequency of and procedures for fire drills.43,45,55 [Recommendation] 3.1.3 The elements of the NFPA 99 Health Care Facili- ties Code36 and the NFPA 101 Life Safety Code37 required by the Centers for Medicare and Med- icaid Services (CMS) must be included in the fire safety plan. [Regulatory Requirement] The CMS requires that health care facilities comply with certain chapters of the 2012 edi- tion of the National Fire Protection Association (NFPA) 99 and the NFPA 101.56-58 There are later versions of the NFPA Codes that provide updated guidance.43,45 3.2 As part of the preprocedural briefing process, the perioperative team should initiate a fire risk assessment to assess for the presence of the three elements of the fire triangle, including • ignition sources, • fuel sources, and • oxidizers. [Recommendation] A fire occurs only when all three elements of the fire triangle are present (Figure 1).33,50 Moderate- quality evidence33,48,51,52,59,60 and clinical guidance33,43 support performing a risk assessment to identify factors that can contribute to a fire. 3.2.1 The fire risk assessment process may include the use of cognitive aids (eg, algorithms, checklists, tools). [Conditional Recommendation] Low-quality evidence32,38,46,48-50,54,61 and clinical guidance33,47 support using algorithms, check- lists, and other tools in the prevention and man- agement of surgical fires. Figure 2 provides an example of a fire risk assessment and algorithm that could be used to support fire prevention interventions based on identified risks. 3.2.2 The perioperative team should collaborate to im- plement interventions (See Recommendations 3.3, 3.4, and 3.5) that address the fire risks iden- tified during the assessment. [Recommendation] 3.2.3 Document the fire risk assessment and that action has been taken to address the identi- fied risks. [Recommendation] 3.3 Use ignition sources (eg, electrosurgical devices) according to the manufacturers’ instructions for use (IFU) and applicable professional guidelines. [Recommendation] Electrosurgical devices,59 powered surgical instru- ments (eg, drills, burrs, saws), fiberoptic light cords,62 and lasers63-65 can become ignition sources when used in the presence of oxidizers (eg, oxygen, nitrous oxide) and fuel sources (eg, alcohol-based skin antiseptic agents, surgical drapes). The most frequently identified ignition source is the electrosurgical unit, which is esti- mated to be involved in about 70% of surgical fires.66 Medical device labels and manufacturers’ written IFU include fire safety information, such as the laser resistance of an endotracheal tube and methods of disposal for equipment (eg, battery packs). 3.4 Prevent contact between fuel sources and ignition sources. [Recommendation] Preventing contact between fuel and ignition sources breaks the fire triangle, thereby preventing fire.33,50 Fuel sources are present in every surgical pro- cedure and can include surgical drapes, alcohol-based skin antiseptics, towels and radiopaque sponges, bone cement, endotracheal tubes, dressings, linens, and gowns.32,33,50,67 Patients can also be fuel sources because gastrointestinal gases,42,68 hair,33,40,41,69 and adipose tis- sue are flammable.32,50 The most common fuel source associated with surgical fires is surgical drapes, which contribute to 81% of surgical fires.70 IGNITION SOURCE FUEL OXIDIZER Figure 1. AORN Fire Triangle The AORN Fire Triangle illustrates the three elements necessary for a fire. I-05_EOC-25_103124.indd 170 I-05_EOC-25_103124.indd 170 11/7/2024 10:45:27 AM 11/7/2024 10:45:27 AM
171 ENVIRONMENT OF CARE Is an alcohol-based skin antiseptic or other flammable solution being used preoperatively? Implement interventions to reduce fire risks associated with identified flammable solutions or antiseptics. Examples can include ■Allowing skin antiseptic agents to dry completely ■Avoiding pooling and absorbing excess solution ■Removing saturated materials from the patient care vicinity Implement interventions to reduce the risks associated with identified oxidizers. Examples can include ■Covering hair near the surgical site with water-soluble gel and using water-based ophthalmic lubricant in the eyes ■Configuring drapes to allow oxygen to flow freely and not accumulate under the drapes ■Using moistened radiopaque sponges near oxidizers and ignition sources ■Notifying the anesthesia professional before using an ignition source (eg, electrosurgical unit, laser, handheld cautery) ■ Anesthesia professional activities › Considering use of a laryngeal mask airway or cuffed endotracheal tube (eg, laser-resistant) if clinically appropriate › Inflating the endotracheal tube cuff with tinted solutions › Evacuating accumulated anesthetic gases/oxygen with suction before an ignition source is used › Using the lowest oxygen concentration needed for adequate oxygenation › Reducing or stopping oxygen/nitrous oxide for __ minute(s) before an ignition source is used › Notifying the team of the presence of an oxygen-enriched environment › Notifying the surgeon when an ignition source can be activated Implement interventions to reduce fire risks associated with the use of identified devices. Examples can include ■Inspecting equipment/devices for defects before use ■Following device manufacturers’ instructions for use and applicable professional guidelines ■Using non-conductive safety holsters or a protective cap as intended ■Using the lowest possible power settings ■Moistening radiopaque sponges/towels used near ignition sources ■Placing equipment (eg, laser, light source) in standby mode when it is not in active use ■Not activating ignition sources in the presence of flammable agents until the agents are dry and vapors have dissipated ■Connecting all cords/cables (eg, fiberoptic) before activating devices and keeping working ends away from potential fuel sources (eg, dry drapes, sponges) ■Verifying water/saline and a fire extinguisher are available ■ Surgeon activities › Ensuring the only person activating a device (eg, electrosurgical unit, laser) is the person using it › Not using an ignition source to enter the bowel or trachea › Waiting for the anesthesia professional’s approval before activating ignition sources in the presence of an oxygen-enriched environment Implement interventions to address fire risks associated with additional ignition sources. Examples can include ■Following device manufacturers’ instructions for use ■Slowly dripping saline on a moving drill, burr, or saw blade ■Placing powered instruments on the Mayo stand or instrument table when they are not in use Is open oxygen or nitrous oxide being administered and/or is the operative site above the xiphoid process (eg, head, neck, chest) or in the oropharynx? Is an electrosurgical unit, laser, or fiberoptic light being used? Are any other ignition sources (eg, defibrillators, drills, saws, burrs) being used? Team agrees to proceed with the planned procedure after implementing fire prevention interventions. YES YES YES NO NO NO NO Refer to the AORN Fire Safety Competency for additional fire prevention interventions. YES Figure 2. Fire Risk Assessment and Prevention Algorithm Resources 1. Apfelbaum JL, Caplan RA, Barker SJ, et al. Practice Advisory for the prevention and management of operating room fires: an updated report by the American Society of Anesthesiologists Task Force on Operating Room Fires. Anesthesiology. 2013;118(2):271-290. 2. Carmack D Jr, Hegeman E, Vizurraga D. Orthopaedic operating room fire risks: FDA database and literature review. JBJS Rev. 2023;11(2). 3. Cognitive aids. Stanford Medicine. Accessed June 21, 2023. https://med.stanford.edu/anesthesia/QualitySafetyandImprovement/projects-and-initiatives/cognitive- aids.html 4. Cowles C, Lake C, Ehrenwerth J. Surgical fire prevention: a review. Anesthesia Patient Safety Foundation. Accessed June 21, 2023. https://www.apsf.org/article/ surgical-fire-prevention-a-review/#:~:text=The%20ASA%20practice%20advisory%20has%20offered%20several%20steps,the%20patient%20to%20safety%20and%20 re-establish%20the%20airway 5. Jones TS, Black IH, Robinson TN, Jones EL. Operating room fires. Anesthesiology. 2019;130(3):492-501. I-05_EOC-25_103124.indd 171 I-05_EOC-25_103124.indd 171 11/7/2024 10:45:28 AM 11/7/2024 10:45:28 AM
172 ENVIRONMENT OF CARE 3.4.1 Before using a skin antiseptic agent, deter- mine its flammability or combustibility rating by reviewing the applicable safety data sheet (SDS). [Recommendation] Skin antiseptic agents (eg, patient skin antisep- tic agents, surgical hand antiseptic agents, alcohol- based hand rubs) can be rated as “combustible” or “flammable” on the SDS. A solution designated as “combustible” has a flash point higher than 100° F (37.8° C). A designation of “flammable” indi- cates a solution has a flash point lower than 100° F (37.8° C). A combustible solution will burn but requires a higher temperature for ignition.71 3.4.2 When applying flammable skin antiseptic agents, prevent the solution from pooling under, on, or near the patient by • placing sterile or clean towels near the sur- gical preparation site to absorb drips and excess solution, • using sterile towels to absorb excess solu- tion from the prepped skin surface or for drying if indicated, • removing materials that become wet with the skin antiseptic agent before draping the patient, and • moving flammable antiseptic solution– soaked materials away from ignition sources and outside of the patient care vicinity (ie, 6 ft away).32,43,50,69,72,73 [Recommendation] See the AORN Guideline for Preoperative Patient Skin Antisepsis74 for additional safety measures. 3.4.3 Follow the skin antiseptic manufacturer’s IFU for the recommended minimum dry time and allow the agent to dry completely before apply- ing sterile surgical drapes.52,53,73 [Recommendation] The NFPA43 states that allowing flammable skin antiseptic agents to dry completely before apply- ing drapes helps to prevent the accumulation of volatile fumes beneath the drapes. The volatile fumes are flammable and can ignite without a con- nection between the ignition source and the anti- septic agent.33,75 3.4.4 For surgical procedures that involve the head or neck, use a water-soluble gel to cover the patient’s hair and use water-based ophthalmic lubricant in the patient’s eyes. [Recommendation] Hair is a fuel source,33,40,41,69 and covering hair with water-soluble gel decreases the risk of combustion.32 Non-water-based lubricants can be fuel sources.32 3.4.5 Store flammable liquids (eg, alcohol-based skin antiseptics, collodion, alcohol-based hand hygiene products) and place alcohol-based hand hygiene product dispensers in accordance with state and local fire regulations.37 [Regulatory Requirement] 3.5 In the presence of an oxidizer-enriched environ- ment, use ignition sources with caution in close proximity to fuel sources. [Recommendation] An environment is considered oxygen- or oxidizer- enriched when the oxygen concentration is greater than 21% by volume.33 The NFPA definition differs slightly and quantifies an oxygen-enriched atmosphere as one that exceeds 23.5% oxygen concentration by vol- ume.43 In an oxygen-enriched environment, fuel sources can ignite at a lower temperature than in ambi- ent or medical air.32,50 Nitrous oxide is considered an oxidizer and requires the same precautions that are used with oxygen.32 3.5.1 The anesthesia professional should verify that the anesthesia circuit and gas connection points are free of leaks. [Recommendation] Leaks in the anesthesia circuit and gas con- nection points can lead to an oxygen-enriched environment under the surgical drapes that increases the risk for fire. The anesthesia circuit includes the endotracheal tube, the seal between the tube and the patient’s airway, the bag reser- voir, and the tubing that leads from the anesthe- sia machine to the endotracheal tube.76 3.5.2 When an open gas delivery system (eg, a nasal cannula) is used and the operative site is above the patient’s xiphoid process (eg, head, neck), • the surgeon should notify the anesthesia professional before using an ignition source and • the anesthesia professional should ◦reduce the oxygen delivery to the mini- mum required to avoid patient hypoxia and stop the use of nitrous oxide, ◦inform the surgeon when to proceed with using the ignition source after allowing time for dissipation of oxidizing agents, and ◦evacuate accumulated anesthetic gas before an ignition source is used in or near an oxidizer-enriched environment. [Recommendation] Cases involving open gas delivery systems and surgical fires have been reported.52,59 A practice advisory from the American Society of Anesthe- siologists recommends interventions to reduce fire risks associated with an oxidizer-enriched I-05_EOC-25_103124.indd 172 I-05_EOC-25_103124.indd 172 11/7/2024 10:45:28 AM 11/7/2024 10:45:28 AM
173 ENVIRONMENT OF CARE environment. There is some conflict as to how long to wait after stopping oxidizer delivery before using an ignition source, with recommen- dations ranging from “at least one minute”32 to “a few minutes,” quantified as 1 to 3 minutes.33 Evacuating anesthetic gases removes excess oxi- dizing agents to create an atmosphere that is closer to ambient air.33,77,78 3.5.3 Use the lowest possible oxygen concentration or flow that provides adequate oxygen satura- tion for a patient who requires supplemental oxygen.33,41,79 [Recommendation] 3.5.4 A laryngeal mask airway or a cuffed endotra- cheal tube may be used when clinically indi- cated and when the patient requires supple- mentary oxygen greater than 30%.33 [Conditional Recommendation] Using a laryngeal mask airway or an endotra- cheal tube reduces the risk of fire by decreasing the oxygen concentration under the drapes and in the patient’s upper airway.33 3.5.5 Minimize the potential for airway fires dur- ing surgical procedures involving the airway by using moistened radiopaque sponges near oxidizers and ignition sources and inflating the endotracheal tube cuff with tinted solution.33 [Recommendation] Fires involving dry radiopaque sponges have been reported.33 Using a tinted solution provides a visual indicator of cuff rupture, particularly in laser procedures.33 3.5.6 When an open gas delivery system is used, con- figure surgical drapes placed near the patient’s head in a manner that allows the oxygen to flow freely and prevents accumulation under the drapes.33,41,70,78,80 [Recommendation] Moderate-quality evidence52,59,78,80 and a prac- tice advisory33 recommend arranging the surgi- cal drapes (eg, avoid tenting, secure drape ends to IV poles) to prevent the accumulation of oxy- gen at the surgical site and under the drapes. 3.5.7 During surgical procedures on anatomical structures that present special fire hazards (eg, bowel, trachea), take additional precau- tions (eg, avoid or minimize use of ignition sources). [Recommendation] Hydrogen and methane, flammable gases often present in the bowel, can ignite when exposed to an ignition source, such as an active electrosurgi- cal device.68 The trachea is an oxygen-enriched environment because of the presence of oxygen and anesthetic gases.65,81 See the AORN Guideline for Electrosurgical Safety82 for additional fire prevention interven- tions related to the use of electrosurgical devices. 3.6 Follow the health care organization’s policies and procedures for communication and fire suppres- sion in the event of a fire. [Recommendation] Following established policies and procedures pro- tects patients and perioperative personnel from injury and can help reduce the severity of sustained injuries. 3.6.1 Any team member who suspects a fire should immediately alert the other perioperative team members. [Recommendation] Flames, smoke, or sounds consistent with a fire or explosion (eg, snap, pop, “foomp”) can indicate the presence of a fire.33 Alerting the team to the presence of a fire allows team members to carry out their responsibilities and decreases the risk of injury to the patient and personnel.32,33 3.6.2 Implement measures identified in the fire safety plan to extinguish the fire. [Recommendation] Extinguishing a fire as quickly as possible decreases the risk of injury to the patient and personnel.32,33,50,54 Saline,32,33,50,54 water,32,33,50,54 and smothering33,54 have been identified as methods to extinguish fires. 3.6.3 In the event of an airway fire, the anesthesia professional should • immediately stop the flow of all airway gases and simultaneously remove the endo- tracheal tube; • remove sponges and any other flammable material from the airway if present; and • pour saline into the airway.33,65 [Recommendation] P The anesthesia professional manages the air- way during procedures involving an intubated patient. Removing the endotracheal tube removes the source of the fuel, and normal saline cools burned tissue.33 Simonini et al65 reported a case of a pediatric airway fire in which these steps were followed and the infant received a burn to the vocal fold but was observed to have completely recovered 1 month later. 3.6.4 In the event of a non-airway fire, immediately stop the flow of all airway gases and simulta- neously remove the surgical drapes and any burning materials from the patient and extin- guish the fire.33 [Recommendation] I-05_EOC-25_103124.indd 173 I-05_EOC-25_103124.indd 173 11/7/2024 10:45:28 AM 11/7/2024 10:45:28 AM
174 ENVIRONMENT OF CARE 3.6.5 After the fuel source has been removed from the patient, reestablish ventilation, assess the patient, and communicate the findings to the perioperative team.33 [Recommendation] 3.7 In collaboration with local authorities, estab- lish evacuation routes for the perioperative environment that are guided by NFPA codes.45 [Recommendation] 3.7.1 Provide education to personnel and emergency responders regarding how to implement the evacuation plan.33,43,47 [Recommendation] 3.7.2 Prominently display evacuation routes in multiple locations throughout the health care facility as indicated in the fire safety plan. [Recommendation] 3.7.3 The evacuation destination should be the closest safe location where patient care can be continued.33,47 [Recommendation] 3.8 After extinguishing a surgical fire, report the event as indicated in the fire safety plan. [Recommendation] 3.8.1 Sequester and retain all items that were involved in the surgical fire for investigation. [Recommendation] Retaining all items that are involved in the fire is necessary to provide evidence for an inves- tigation.32,63 Investigations examining the factors that contributed to the fire can be performed by quality or risk management personnel but can also involve the local fire department.32 3.9 Personnel involved in the surgical fire should be given the opportunity to participate in team debriefing and be screened for symptoms of work- place trauma (eg, rumination about the event, sleep disturbances) before returning to clinical work. [Recommendation] An event like a surgical fire can be a traumatic experience for those involved. Guidance from the Association of Anaesthetists and the Intensive Care Society47 recommends that all perioperative team members who are involved in a surgical fire attend an operational debrief, be assessed by an occupational health professional, and have access and time to use counseling services after the event. 3.10 Disconnect from the electrical power source any equipment that emits unanticipated smoke, whether in use or not. Move the equipment and all of the accessories in use to a safe area if it is safe to do so. [Recommendation] Smoke can indicate the presence of a fire, and equipment can serve as an ignition source for nearby items.83 Disconnecting any equipment that is emitting smoke from the electrical power source and moving it out of the OR decreases the risk to the patient and perioperative team members in that room. 3.10.1 Evacuate the room if equipment that is emitting smoke cannot be removed safely. [Recommendation] 3.11 Select fire extinguishers according to standards established by the NFPA 1084 and the authority having jurisdiction. Factors that assist in deter- mining the correct type of fire extinguishers include the • presence of electrical equipment,84 • hazards that are present and may create adverse chemical reactions with the extinguish- ing agent,84 • maintenance requirements,84 • potential fire size,84 • physical abilities of the potential users,84 • ease of use,84 and • types of fuels that are present.84 [Recommendation] Guidance about which extinguishers are safe to use in the OR conflicts. The NFPA 9943 recommends that either a water mist or carbon dioxide fire extin- guisher be used in the OR. ECRI32 recommends using carbon dioxide fire extinguishers in the OR and dis- courages the use of other types of extinguishers in this setting because of concerns related to contami- nation and toxicity. 3.11.1 Place fire extinguishers in locations as indi- cated in the fire safety plan. [Recommendation] 3.11.2 Establish and implement a schedule and pro- cess to inspect, test, and maintain fire extin- guishing equipment and supplies in the peri- operative setting.84 [Recommendation] 3.11.3 Fire extinguishers should only be used if appropriate for the conditions of the fire (eg, size, type of fuels involved, hazards present) and if all other methods of suppression fail. [Recommendation] Extinguishing a fire using noncombustible and nonflammable solutions or a smothering technique can be faster than obtaining a fire extinguisher.32 3.12 Do not use fire blankets in the OR.32 [Recommendation] Fire blankets can trap fire next to or under the patient and cause more harm. Fire blankets are often I-05_EOC-25_103124.indd 174 I-05_EOC-25_103124.indd 174 11/7/2024 10:45:28 AM 11/7/2024 10:45:28 AM
175 ENVIRONMENT OF CARE made of wool and can burn in an oxygen-enriched environment.32 Additionally, application of a fire blanket could displace instruments, contaminate the wound, or cause a fire to spread.32 3.13 Perioperative team members should • know the location of medical gas control valves, • be able to identify the areas that the valves sup- ply, and • have the ability to turn the control valves off in the event of a fire. [Recommendation] Removing the oxidizer by turning off the medical gas supply breaks the fire triangle.33,83 3.13.1 Do not block access to fire pull alarms, medi- cal gas control valves, or electrical panels.45 [Recommendation] 3.14 The health care organization may evaluate acces- sories and devices that are intended to reduce the risk of perioperative fires. [Conditional Recommendation] High-quality evidence supports the utility of an accessory intended to reduce the risk of surgical fires.85 In a quasi-experimental study, Roy et al85 tested the effectiveness of a fiberoptic light cord cover in preventing thermal damage to surgical cot- ton towels and surgical drapes in ambient room air and oxygen-enriched environments. The researchers found that when the fiberoptic cord cover was applied according to the manufacturer’s IFU, there was no thermal damage to the surgical towels or drapes under any of the tested conditions, and the temperature at the distal end of the tested light cords was about 50° C (122° F) compared to 240° C (464° F) or higher without the cover. The researchers concluded that using a protective cord cover as directed by the device manufacturer’s IFU could reduce the risk of perioperative burns and fire asso- ciated with using fiberoptic light cords. Additional research is needed to fully evaluate the effectiveness of devices intended to reduce the risk of periopera- tive fires, including the ways in which their use might influence workflows and patient outcomes. 3.15 Provide education and competency verification activities for perioperative team members, according to their roles, on the following topics: • the components of the fire triangle and how to safely manage them in the perioperative setting,33,50,67 • fire risk assessment33,34,40,48,51,60,67 • the locations of and safe use of fire extinguishers,32,54,61 • evacuation routes,43 • medical gas valve locations and their operation,33,83 • the location of shut-off controls and procedures for turning off electrical systems,32 • the location of fire alarm pull stations,32 • how and when to activate the fire safety and evacuation plan,32,47 • the use of cognitive aids in supporting fire pre- vention and management,38,46-50 and • the roles and responsibilities of each periopera- tive team member in various fire scenarios.33,42,44 [Recommendation] A large body of evidence supports education and training for perioperative personnel that includes fire safety protocols, management of surgical fires, and participation in mock fire drills.32-34,39,47,50-52,55,60,62,67,86-88 Fire safety training prepares the perioperative team to respond quickly and appropriately in the event of a fire. 3.15.1 Include all members of the perioperative team (eg, perioperative RNs, surgical technologists, surgeons, anesthesia professionals, surgical assistants) in fire safety training and drills. [Recommendation] Evidence supports including the entire perioperative team in team training for fire safety.32,33,39,50,55,67,86 The literature indicates that training that includes all members of the team improves communication and teamwork and can lead to a more rapid response and potentially better outcomes in the event of a surgical fire. 3.15.2 Fire safety training may include the use of sim- ulation and technology (eg, virtual reality [VR] technology, a manikin simulator). [Conditional Recommendation] Moderate-quality evidence60,86,89,90 and clinical guidance47 support the use of simulation-based training to give trainees the opportunity to prac- tice fire prevention and management skills in a safe environment utilizing scenarios that are more realistic than those of traditional mock fire drills. Three nonexperimental studies evaluated the performance of different VR simulation training platforms and found that users demonstrated improved competency in completing simula- tion scenarios involving surgical fires with real- time feedback guiding their behavior.89-91 The VR platforms studied were limited to a single user at a time; advancements in technology that allow multiple users to interact simultaneously as a team in the virtual environment will be an important focus for future research. I-05_EOC-25_103124.indd 175 I-05_EOC-25_103124.indd 175 11/7/2024 10:45:28 AM 11/7/2024 10:45:28 AM
176 ENVIRONMENT OF CARE 3.15.3 Hold regularly scheduled fire drills as indi- cated in the fire safety plan. [Recommendation] The NFPA 10145 recommends that fire drills be held at least quarterly on each shift. The NFPA 9943 recommends holding fire drills annually or as determined by the relevant building code. The local authority having jurisdiction might follow a different edition of the NFPA code. 4. Electrical Equipment 4.1 Inspect all electrical equipment, including loaned equipment, for signs of wear (eg, frayed cords) and damage • before each use and • according to a schedule established by the organization. [Recommendation] Damaged electrical equipment and power cords can create unsafe conditions that contribute to the harm of patients or personnel. Fires related to mal- functioning equipment have been reported in the literature.52,83 4.2 Collaborate with biomedical engineering person- nel and consult the manufacturers’ instructions for use to determine the frequency and nature of testing and maintenance for patient care–related electrical equipment used in the perioperative suite. [Recommendation] The NFPA recommends that electrical testing be conducted when equipment is first put into service and after repairs or modifications that could have compromised electrical safety.43 Fires associated with electrical malfunction of equipment have been reported, suggesting a need for regular inspection, testing, and maintenance of equipment to support safety and reduce the risk for fire.52,83 4.3 Implement the following safe practices when using devices with electrical power cords: • use power cords that are original to the device and suitable for the application (eg, adequately long)43; • if a replacement cord or extension cord is needed, verify that it meets the electrical char- acteristics of the original device cord (eg, grounding resistance, polarization, voltage, ampacity)43; • when using an extension cord, plug it directly into a power source, and do not connect it to another extension cord43; • inspect the physical integrity of the power cord, attachment plug, and strain relief before use43; • remove damaged power cords and equipment from use; and • secure power cords using devices designed for that purpose.23 [Recommendation] Power cords that are of insufficient length can create a risk for tripping or accidental unplugging of equipment.23 Replacing a device’s cord could nullify the device warranty or cause damage to the device if the replacement cord does not have the same elec- trical characteristics as the original power cord. Safely securing cords using devices intended for this purpose helps prevent trips and falls.23 4.4 Implement the following safe practices when using relocatable power taps (eg, multiple outlet connectors, power strips, portable outlets): • securely attach the relocatable power tap to a pole, cart, table, pedestal, or boom43; • consult with biomedical engineers to predeter- mine what equipment can be safely accommo- dated by the portable outlet43; • do not plug the portable outlet into another portable outlet or extension cord43; and • establish and implement a process and schedule in collaboration with biomedical engineering personnel to verify integrity of relocatable power taps used in the perioperative setting.43 [Recommendation] Using a relocatable power tap allows multiple pieces of equipment to be plugged into a single multi-outlet connection with a single cord that plugs into a power outlet, eliminating multiple cords on the floor for multiple pieces of equipment. This can help reduce the risk of slips, trips, and falls in the OR. 4.5 Labels (eg, description, serial number) that can be cleaned and disinfected may be used to match device charging cords and adapters to equipment. [Conditional Recommendation] Device charging cords and adapters can look simi- lar but have different voltage requirements. One case report documented an incident in which use of an incorrect charging device caused an activated clotting time monitor to overheat and shut down during a cardiac procedure.92 Further investigation revealed that other devices used by the team had the same size charging socket but different energy out- puts, meaning the wrong charger could be plugged into a device and create a fire risk if allowed to charge unsupervised.92 4.6 Provide education to and verify competency of perioperative team members on the safe use of electrical equipment used within the periopera- tive suite.43 [Recommendation] I-05_EOC-25_103124.indd 176 I-05_EOC-25_103124.indd 176 11/7/2024 10:45:28 AM 11/7/2024 10:45:28 AM
177 ENVIRONMENT OF CARE 5. Warming Cabinets 5.1 Convene an interdisciplinary team that includes perioperative RNs, anesthesia professionals, bio- medical engineering personnel, and other stake- holders identified by the organization to estab- lish and set maximum temperature limits for fluid-warming cabinets and blanket-warming cabinets. [Recommendation] 5.1.1 When determining maximum temperature lim- its for blanket warming cabinets, the interdisci- plinary team should review the cabinet manu- facturer’s IFU and conduct a risk assessment. [Recommendation] Evidence on the optimal temperature for blanket-warming cabinets conflicts. ECRI reviewed multiple cases of patients from three different hospitals who were burned by blankets warmed in cabinets set higher than 130° F (54° C). Impor- tantly, the patients were sedated or anesthetized when the folded or rolled blankets were applied.93 ECRI recommends a maximum temperature of 130° F for blanket-warming cabinets.94 A quasi-experimental study95 and two ran- domized controlled trials96,97 found that blankets heated to 155° F and 200° F (68° C and 93° C), respectively, improved thermal comfort com- pared to blankets that were warmed to 110° F or 130° F (43° C or 54° C). None of the studies reported any thermal injuries resulting from contact with the warmed blankets. Study participants were either covered from neck to toes with unfolded blankets95,96 or had a rolled blanket placed under the neck and a folded blanket placed under the lumbar spine area.97 Limitations for the random- ized controlled trials included small sample sizes and that participants were healthy, awake adults who were not patients.96,97 The quasi-experimental study had a larger, adequately powered sample of patients from the postanesthesia care unit who were also awake enough to respond to questions regarding ther- mal comfort.95 The researchers in all three stud- ies concluded that it was safe to use blankets from warming cabinets that were set to 155° F or 200° F but recommended additional research with larger sample sizes and more diverse patient populations to confirm their findings.95-97 5.1.2 When determining the maximum temperature and length of time solutions can remain in the warming cabinet, the interdisciplinary team should review the solution manufacturers’ IFU. [Recommendation] Solution manufacturers’ recommendations for maximum temperature setting, time limit that solutions can remain in the warming device, and solution use after removal from a warming device vary. Manufacturers’ settings are deter- mined by the stability of the container and the solution.94 5.2 Store solutions and linens (eg, blankets) in sepa- rate warming cabinets or in cabinets with sepa- rate compartments that have independent tem- perature controls. [Recommendation] The danger of burns from heated solutions, blan- kets, or linens is increased in the perioperative set- ting because patients are often unconscious or sedated and unable to respond to an increase in tem- perature or communicate discomfort. Even when solutions and blankets do not feel warm to the touch, heat continues to build in these items and can be transferred to the patient.94 Fluids cannot be warmed to the same tempera- ture as blankets because fluids attain a higher tem- perature and retain the temperature longer, pre- senting a greater risk for thermal injury.94 Storing solutions and linens in separate warming cabinets or compartments allows these items to be kept at dif- ferent temperatures for patient safety.55 5.2.1 Label warming cabinets to identify the items that can be placed in the cabinet and the maxi- mum permissible temperature settings. If the cabinet has separate compartments, label each compartment.94 [Recommendation] 5.3 Set, maintain, and monitor warming cabinet tem- peratures according to the manufacturer’s IFU and organizational policy. [Recommendation] Monitoring the temperature of warming cabinets is necessary to verify that temperature settings are maintained within specified limits.94 5.3.1 Equip warming cabinets with an alarm mecha- nism that will alert personnel to an equipment failure. [Recommendation] An alert alarm notifies personnel so that corrective action can be taken in a timely man- ner. Injuries to the patient can result from irrigation solution being warmed to high tem- peratures. In one report, a patient experienced full-thickness skin burns and joint damage from irrigation solutions that were warmed in a cabinet in which the temperature ranged from 100.4° F (38° C) on the top shelf to 118.4° F (48° C) on the bottom shelf.98 I-05_EOC-25_103124.indd 177 I-05_EOC-25_103124.indd 177 11/7/2024 10:45:28 AM 11/7/2024 10:45:28 AM
178 ENVIRONMENT OF CARE 5.3.2 In collaboration with biomedical engineering personnel, establish and implement a sched- ule for testing and maintenance of warming cabinets that includes verifying the accuracy of warming cabinet temperature settings.94 [Recommendation] 5.3.3 Take action when a warming cabinet malfunc- tions, including • removing the cabinet from service; • labeling the cabinet as out of service; • removing all items from the cabinet; • not using warmed items if they are overheated; • following the solution manufacturers’ written IFU to determine the usability of solutions; and • following organizational procedures for reporting the malfunction to biomedical engineering professionals for repair and maintenance. [Recommendation] 5.4 When solutions are placed in warming cabinets, follow organizational policy in labeling the contain- ers with the date of placement in the warmer or the date they should be removed from the warmer. [Recommendation] Labeling identifies when a solution has reached its maximum shelf life and prevents overheating related to being left in the warmer too long. See the AORN Guideline for Medication Safety1 for recommendations on separate storage of irrigation and IV solutions. 5.5 When removing solutions from a warming cabinet for the purpose of administration, verify the temper- ature setting of the warming cabinet before adminis- tering or dispensing the warmed solution to the ster- ile field. [Recommendation] Thermal injuries have been associated with the administration of overheated solutions.98,99 Verifying the temperature setting of the warming cabinet when removing solutions for administration will help verify that the solution was stored at the rec- ommended temperature and not accidentally placed in a warming cabinet or compartment set to a higher temperature for blanket storage. See the AORN Guideline for Sterile Technique100 and the Guideline for Medication Safety1 for guid- ance on transferring solutions to the sterile field. 5.6 Warm solutions intended for IV administra- tion using devices designed for this purpose. [Recommendation] The temperature of solutions warmed in warming cabinets can vary depending on the design of the cabinet, load configuration, and the elapsed time from the removal of the solution from the cabinet to administration of the solution to the patient.94 Using devices designed to warm solutions for infusion (eg, in-line solution warmers) can provide a more accu- rate and consistent fluid temperature.94 5.7 Do not place patient skin antiseptic agents in a warming cabinet unless this is permitted by the manufacturer’s IFU. [Recommendation] Heating could alter the chemical composition or effectiveness of the skin antiseptic. See the AORN Guideline for Preoperative Patient Skin Antisepsis74 for more information. 5.8 Maintain a warming cabinet capacity that is suffi- cient to support the anticipated demand for warmed items. [Recommendation] Perioperative personnel have been reported to engage in unsafe blanket warming practices, includ- ing increasing the temperature of the warmer in an effort to heat items more quickly so that they can be used and the warmer restocked, which can cause overheating of the blankets and potentially lead to thermal injuries.94 5.9 Provide education to and verify competency of perioperative team members on the safe use of warming cabinets in the perioperative suite.94 [Recommendation] 6. Medical Gas Cylinders 6.1 Determine storage conditions for medical gases by the volume stored in a location, the need for immediate use, and regulatory requirements. [Recommendation] At the time of publication of this guideline, CMS requires that health care facilities comply with cer- tain chapters of the 2012 edition of the NFPA 99 Health Care Facilities Code.56-58 There are later versions of NFPA 99 that also provide guidance.43 The NFPA and regulatory agencies have determined medical gas storage condition requirements.36 6.1.1 Store an adequate emergency supply of oxy- gen at the facility to provide an uninterrupted supply for 1 day.43 [Recommendation] 6.1.2 Medical gases must be stored in secured loca- tions and separately from industrial gases.36,64 [Regulatory Requirement] I-05_EOC-25_103124.indd 178 I-05_EOC-25_103124.indd 178 11/7/2024 10:45:28 AM 11/7/2024 10:45:28 AM
179 ENVIRONMENT OF CARE The US Food and Drug Administration (FDA) considers compressed medical gases to be drugs for dispensing by prescription only and requires them to be secured and protected from unau- thorized access.64,101 6.1.3 Store medical gas cylinders used in the periop- erative setting indoors and • in a room with a fire resistance rating described in NFPA 99, • in a holder or storage rack with a chain-like securing device, and • away from heat sources.43 [Recommendation] Securing cylinders with a chain-like securing device or in a rack prevents the cylinders from falling over.43 6.1.4 Do not store medical gas cylinders in an egress hallway.45 [Recommendation] 6.1.5 Separate empty medical gas cylinders from full cylinders and identify empty versus full cylinders.43 [Recommendation] Storing empty cylinders separately minimizes the risk of connecting to an empty cylinder and delaying administration of vital gases to the patient. 6.2 Transport medical gas cylinders using carriers or holders designed to prevent the cylinder from tipping or being dropped or damaged. [Recommendation] Transporting a gas cylinder without using a car- rier increases the potential for damage to the cylin- der, which could cause the cylinder to rupture or become a projectile and lead to severe injury.102 6.3 Cylinder valve protection caps should be left in place and secured unless gas cylinders are in use or connected for use.43 [Recommendation] The cylinder valve cap protects the valve from breaking or becoming damaged if the cylinder falls.102 6.4 Do not alter the fittings on medical gas cylinders and hoses.43 [Recommendation] Serious injuries and deaths have resulted from alteration of the pin-index safety system, thereby permitting delivery of an incorrect gas into the med- ical gas administration system.64 6.5 Use regulators or other flow control devices with the gases for which they are designed and intended.43,102 [Recommendation] 6.5.1 Inspect the regulator and associated compo- nents for signs of damage or wear before use and replace any items found to be defective.102 [Recommendation] 6.6 Implement safe practices when using medical gas cylinders and accessories, including • checking for the appropriate label, pin-index safety system connector, and color coding before use,43,102 • inspecting the cylinder and cylinder valve for damage before use,102 • directing the cylinder valve outlet away from personnel and standing to the side when open- ing the valve,43 • releasing a small amount of gas before attach- ing the regulator after opening a cylinder valve to eliminate dust,43,102 • tightening the regulator connection with a wrench until it is firmly secured,43 • opening the valve slowly to a full-open position for use,43 and • fully closing valves during storage to avoid leakage.43 [Recommendation] Improper handling or use of medical gas cylinders can result in contamination of the gas, leakage of the contents into the environment, or potential injury to patients or personnel.43 The color of the cylinder, written labels, and a unique pin-index safety system connector are used to clearly identify the medical gas contained within a medical gas cylinder.43 The pin-index safety system connector for differ- ent medical gases prevents connecting the wrong gas to the delivery system.43 The FDA requires manufac- turers of medical gases to use specific colors (eg, green for oxygen, gray for carbon dioxide, blue for nitrous oxide) on the gas cylinder to identify the cylinder con- tents.103 Serious injuries and deaths have resulted from the use of incorrectly identified medical gas.64 6.6.1 For surgical suites that close for business at the end of the day, establish a process for checking gas cylinder valves and oxygen delivery unit valves (eg, anesthesia machines, flow meters) at the end of every business day to verify that they are in the off position. [Recommendation] Confirming that gas cylinder valves are closed at the end of the business day reduces the risk of unnecessary gas depletion when an area is unattended. 6.7 Protect oxygen cylinders and associated equip- ment from contact with oil, grease, or other flam- mable materials.43 [Recommendation] Avoiding contact between oxidizers and fuel sources contributes to fire prevention. I-05_EOC-25_103124.indd 179 I-05_EOC-25_103124.indd 179 11/7/2024 10:45:28 AM 11/7/2024 10:45:28 AM
180 ENVIRONMENT OF CARE 6.8 Liquid oxygen containers must be handled, filled, stored, and transported according to state and fed- eral regulations and manufacturers’ written instructions and labeling.36 [Regulatory Requirement] 6.8.1 Store liquid oxygen containers according to the manufacturer’s IFU and in a location where they • are secured to prevent them from tipping over, • do not interfere with foot traffic, • are not exposed to open flames or high- temperature devices, and • are not subject to damage from falling devices.43 [Recommendation] 6.9 Provide education to and verify competency of perioperative team members who handle medical gas cylinders.36 [Regulatory Requirement] 6.9.1 Education should include the following: • the clinical uses and hazards associated with the types of medical gases that are used in the facility,102 • the components of medical gas cylinders and their accessories (eg, labels, color cod- ing, pin-index safety system connectors, hoses, regulators, gaskets, washers),64,102 • safe storage conditions (eg, storage loca- tions, signage, separation of full and empty cylinders, securement devices to prevent tipping),102 • procedures for safe handling of medical gas cylinders (eg, how to operate cylinder valves),102 • safe transportation practices (eg, securing the cylinder in a holder or carrier for trans- port),43,102 and • procedures for reporting adverse events and items in need of replacement or repair. [Recommendation] 7. Waste Anesthetic Gases 7.1 Convene an interdisciplinary team with the respon- sibility and authority to establish and implement a waste anesthetic gas (WAG) management program that aligns with recommendations from the Occupa- tional Safety and Health Administration (OSHA),76 NIOSH,104,105 and NFPA.43 [Recommendation] P Moderate-quality evidence106-109 and guidance from OSHA,76 NIOSH,104,105 and NFPA43 support inter- ventions to reduce exposure to WAGs. However, some of the literature conflicts on the health effects of WAGs.104,106-108,110-113 A NIOSH report shows inconsis- tencies in the literature regarding the effects of WAGs, discusses the means of exposure, and pro- vides guidance for reducing exposures.104 The adverse health effects of exposure to trace amounts of WAGs are currently unknown. The Inter- national Agency for Research on Cancer classifies volatile anesthetics as group 3 based on a lack of evi- dence suggesting that these agents are carcinogenic to humans.114,115 The recommended exposure limit (REL) set by NIOSH for nitrous oxide is 25 parts per million (ppm) as a time-weighted average during anesthesia administration.105 NIOSH also rec- ommends limiting exposure to halogenated anes- thetic agents to no more than 2 ppm over a sampling period of 1 hour.105 There are no legally enforceable (ie, regulatory) permissible exposure limits from OSHA for nitrous oxide or halogenated anes- thetic agents (eg, desflurane, enflurane, halothane, isoflurane, sevoflurane).76 In a literature review, Anderson and Goldman112 reported a link between WAGs and an elevated risk of spontaneous abortion, congenital anomalies, and infertility. The review authors also pointed out that the NIOSH RELs for nitrous oxide and halogenated agents might be outdated because they were calcu- lated with the purpose of protecting mental perfor- mance and dexterity rather than adverse reproduc- tive outcomes. Additionally, the NIOSH REL for halogenated agents was based on testing of older agents and might not be applicable to newer, more commonly used halogenated agents like isoflurane and sevoflurane.112 In a study of 15,317 children born to 9,433 nurses who were exposed to WAGs (ie, halothane, isoflu- rane, sevoflurane, nitrous oxide), researchers identi- fied an association between maternal exposure to anesthetic gases and the development of congenital anomalies in the children.116 The study results sug- gested that the anomalies correlated with the type of WAG to which the mother was exposed, with cardiac anomalies being more prevalent with exposure to halogenated agents and integument anomalies being prevalent with exposure to nitrous oxide and halo- genated agents.116 Additional research is needed to establish a causal relationship between WAG exposure and reproduc- tive outcomes in humans; however, including indi- viduals who are pregnant in research studies exam- ining WAG exposure is ethically problematic and it may be difficult to close this research gap. Magnavita et al110 presented a case report of a female anesthesiologist who developed a form of scleroderma, cutaneous systemic sclerosis, after occupational exposure to volatile anesthetic gases (eg, halothane, enflurane, isoflurane, sevoflurane) I-05_EOC-25_103124.indd 180 I-05_EOC-25_103124.indd 180 11/7/2024 10:45:28 AM 11/7/2024 10:45:28 AM
181 ENVIRONMENT OF CARE during a 10-year period of working in pediatric ORs. The case report authors concluded that occupational factors could have contributed to the diagnosis of scleroderma and that additional study is needed to better understand the effects of occupational expo- sure to volatile anesthetic gases on workers’ health.110 7.1.1 The interdisciplinary team responsible for WAGs should include anesthesia profession- als, perioperative RNs, surgeons, facility engi- neers, biomedical engineers, safety officers, occupational health professionals, and other stakeholders identified by the organization. [Recommendation] 7.1.2 The WAG management program should describe the engineering controls, adminis- trative controls, work practice controls, and personal protective equipment (PPE) imple- mented to reduce worker exposure to WAGs. [Recommendation] A nonexperimental study117 and guidance from OSHA76 and NIOSH105 support using a hierarchi- cal approach to reduce exposure to workplace hazards by implementing controls in decreas- ing order of effectiveness: engineering controls, administrative controls, work practice controls, and PPE. Figure 3 shows examples of different types of controls that can be implemented as part of a WAG management program. 7.2 The WAG management program should also describe • anesthesia delivery and WAG disposal systems that are used in the facility; • methods for verifying functionality of anesthe- sia delivery and WAG disposal systems; and • preventive maintenance of anesthesia delivery and WAG disposal systems, in accordance with the manufacturer’s written instructions and organizational policy and procedures.76,105 [Recommendation] OSHA recommends that a program for regularly scheduled inspection and maintenance of all anes- thesia machines be in place and be conducted at least every 4 months by qualified personnel.118 See the AORN Guideline for Design and Mainte- nance of the Surgical Suite2 for additional guidance related to WAG disposal systems. 8. Latex-Safe Environment 8.1 Convene an interdisciplinary team with the responsibility and authority to develop and implement a latex safety program to mitigate the risks of latex allergy and sensitivity for patients and personnel. [Recommendation] Moderate-quality evidence and a clinical practice guideline establish that frequent exposure to natural rubber latex in the health care environment is a risk ENGINEERING CONTROLS ADMINISTRATIVE AND WORK PRACTICE CONTROLS PPE* (FOR SPILLS) •Waste anesthetic gas disposal systems1-5 •Room dilution ventilation1-3,5 •Key filler devices for filling vaporizers1 •Training and education1-5 •Scheduled testing and maintenance of anesthesia equipment2-5 •Safe anesthesia gas administration techniques1-5 (eg, use cuffed endotracheal tubes, use a low flow volume, turn off the gas when the mask is not on the patient) •Gloves1,3 •Eye protection3 •Face shield3 •Protective clothing3 •Full facepiece respirator3 •Ambient air monitoring2-5 •Medical surveillance1-5 •Anesthesia machine checks for gas leaks1-5 •Safe vaporizer fill technique1-5 •Clean up of spilled anesthetic agents1,3 MOST EFFECTIVE LEAST EFFECTIVE *Personal protective equipment Figure 3. Controls to Mitigate Waste Anesthetic Gas Hazards I-05_EOC-25_103124.indd 181 I-05_EOC-25_103124.indd 181 11/7/2024 10:45:28 AM 11/7/2024 10:45:28 AM
182 ENVIRONMENT OF CARE factor for the development of latex sensitivity,119-124 latex allergy,119-126 and anaphylaxis,119,120,123,125,126 among patients and health care workers (eg, RNs, clinical support personnel, environmental services personnel, physicians, physiotherapists, technicians).119,120,122-126 8.1.1 The interdisciplinary team should include perioperative RNs, surgeons, anesthesia pro- fessionals, surgical technologists, informatics